#ExistInterpDataSet>
| Interpretive Data: |
#ExistInterpData>Serum is the preferred specimen for evaluating metal ion release from metal-on-metal joint arthroplasty. Metal ion testing of joint fluid may be complementary to serum testing, but reference intervals for joint fluid are not established. Concentrations of cobalt may exceed 100 ug/L in fluid collected from an affected joint.
*ExistInterpData>
|
*ExistInterpDataSet>
#ExistNote>
| Note: |
Contamination from noncertified trace element-free tubes may cause elevated results.
|
*ExistNote>
#ExistCPT>
| CPT Code(s): |
83018
|
*ExistCPT>
#ExistCrossReferences>
Cross References: |
Hip Replacement (Cobalt, Joint Fluid), Joint, Arthroplasty (Cobalt, Joint Fluid), Knee Replacement (Cobalt, Joint Fluid), Metal Ion Testing (Cobalt, Joint Fluid), Synovial Fluid (Cobalt, Joint Fluid) |