ARUP's Laboratory Test Directory

Mumps Virus Antibody, IgM : 0099589

Mnemonic: MUMPS IGM

Methodology: Semi-Quantitative Enzyme-Linked Immunosorbent Assay
Performed: Mon, Wed, Fri
Reported: 1-6 days
Specimen Required: Collect: Serum separator tube.

Specimen Preparation: Separate serum from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.2 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens. Mark specimens plainly as "acute" or "convalescent."

Storage/Transport Temperature: Refrigerated.

Unacceptable Conditions: Contaminated, hemolyzed, heat-inactivated, or severely lipemic specimens.

Stability (collection to initiation of testing): After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)

Reference Interval:
0.79 IV or less: Negative - No significant level of detectable IgM antibody to Mumps virus.
0.80-1.20 IV: Equivocal - Borderline levels of IgM antibody to Mumps virus. Repeat testing in 10-14 days may be helpful.
1.21 IV or greater: Positive - Presence of IgM antibody to Mumps virus detected, which may indicate a current or recent infection. However, low levels of IgM antibody may occasionally persist for more than 12 months post-infection or immunization.
CPT Code(s): 86735
Cross References: MMR (Mumps Virus Antibody, IgM), Parotitis (Mumps Virus Antibody, IgM)
 
 

 

 

 