ARUP's Laboratory Test Directory

Boron, Serum or Plasma : 0091330

Mnemonic: BORON SP

Methodology: Quantitative Inductively Coupled Plasma-Optical Emission Spectrometry
Performed: Varies
Reported: 3-9 days
Specimen Required: Collect: Royal blue, plastic (trace metal-free; EDTA) or royal blue, plastic (trace metal-free; no additive).

Specimen Preparation: Separate from cells within 2 hours of draw. Transfer 2 mL serum or plasma to an ARUP Trace Element-Free Transport Tube (ARUP supply #43116). Available online through eSupply using ARUP Connect™ or contact ARUP Client Services at (800) 522-2787. (Min: 0.7 mL)

Storage/Transport Temperature: Refrigerated. Also acceptable: Room temperature or frozen.

Unacceptable Conditions: Glass containers or separator tubes.

Stability (collection to initiation of testing): Ambient: 1 month; Refrigerated: 1 month; Frozen: 1 month

Reference Interval:
By report
CPT Code(s): 83018
Cross References: B (Boron, Serum or Plasma)
 
 

 

 

 