#ExistMethodology>
| Methodology: |
Fluorescence Polarization Immunoassay
|
*ExistMethodology>
#ExistPerformed>
| Performed: |
Sun-Sat
|
*ExistPerformed>
#ExistReported>
| Reported: |
Within 24 hours
|
*ExistReported>
#ExistSpecRequirements>
| Specimen Required: |
#ExistPATIENTPREP>Patient Prep: Draw specimens 12 hours after initiating therapy for arrhythmia prophylaxis, then every 24 hours thereafter.
*ExistPATIENTPREP>
#ExistCollect>Collect: Plain red. Also acceptable: green (sodium heparin).
*ExistCollect>
#ExistSPECIMENPREPARATION>Specimen Preparation: Separate serum from cells immediately. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.5 mL)
*ExistSPECIMENPREPARATION>
#ExistSPECTRANSPORT>Storage/Transport Temperature: Refrigerated.
*ExistSPECTRANSPORT>
#ExistConditions>Unacceptable Conditions: Separator tubes, Lavender (EDTA), or gray (sodium fluoride/potassium oxalate).
*ExistConditions>
#ExistStability>Stability (collection to initiation of testing): After separation from cells: Ambient: 1 week; Refrigerated: 1 week; Frozen: 1 month
*ExistStability>
|
*ExistSpecRequirements>
|
|