ARUP's Laboratory Test Directory

Complement Activity Enzyme Immunoassay, Total : 0050198

Mnemonic: CH50

Methodology: Semi-Quantitative Enzyme-Linked Immunosorbent Assay
Performed: Mon-Fri
Reported: 1-4 days
Specimen Required: Collect: Plain red.

Specimen Preparation: Allow specimen to clot for one hour at room temperature. Separate serum from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.3 mL)

Storage/Transport Temperature: CRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.

Unacceptable Conditions: Separator tubes. Specimens left to clot at 2-8°C. Specimens exposed to repeated freeze/thaw cycles. Non-frozen specimens.

Stability (collection to initiation of testing): After separation from cells: Ambient: 2 hours; Refrigerated: Unacceptable; Frozen: 2 weeks

Reference Interval:
Effective May 16, 2011

60-144 CAE Units
CPT Code(s): 86162
Cross References: CH100 (Complement Activity Enzyme Immunoassay, Total), CH50 (Complement Activity Enzyme Immunoassay, Total), Classic Complement Pathway Assessment-CH100 (Complement Activity Enzyme Immunoassay, Total), Complement CH100, Total (Complement Activity Enzyme Immunoassay, Total), Total Complement CH100 (Complement Activity Enzyme Immunoassay, Total), Total Complement CH50 (Complement Activity Enzyme Immunoassay, Total)
 
 

 

 

 
All ARUP Sites:        www.aruplab.com     ·     www.arupconsult.com     ·     www.arup.utah.edu     ·     www.childx.org     ·     www.utahblood.org